Fechar

1. Identificação
Tipo de ReferênciaArtigo em Evento (Conference Proceedings)
Sitemtc-m16c.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
Identificador6qtX3pFwXQZGivnJSY/HKJpy
Repositóriosid.inpe.br/MTC-m13@80/2005/10.13.17.14
Última Atualização2006:06.14.04.43.12 (UTC) marciana
Repositório de Metadadossid.inpe.br/MTC-m13@80/2005/10.13.17.14.11
Última Atualização dos Metadados2018:06.04.04.12.28 (UTC) administrator
Chave SecundáriaINPE-13192-PRE/8448
Chave de CitaçãoBertagnolliPCMPSNYS:2005:MoCáCo
TítuloModelo para Cálculo da Coluna Total de Ozônio usando Dados do Espectroradiômetro do Observatório Espacial do Sul
FormatoCD-ROM; On-line; Papel.
Ano2005
Data de Acesso08 maio 2024
Tipo SecundárioPRE CI
Número de Arquivos1
Tamanho224 KiB
2. Contextualização
Autor1 Bertagnolli, Caroline
2 Peres, Rafael
3 Carbone, Samara
4 Manfro, Robinson L.
5 Pinheiro, Damaris K.
6 Schuch, Augusta A. M. P.
7 Nozawa, H.
8 Yamamoto, H.
9 Schuch, Nelson J.
Grupo1 INPE-MCT-BR
2 INPE-MCT-BR
3 INPE-MCT-BR
4 INPE-MCT-BR
5
6
7
8
9 INPE-MCT-BR
Nome do EventoInternational Congress of the Brazilian Geophysical Society, 9.
Tipo TerciárioArtigo
Histórico (UTC)2005-11-24 11:12:06 :: seeger05 -> marciana ::
2006-03-08 15:10:30 :: marciana -> banon ::
2006-09-27 20:36:45 :: banon -> administrator ::
2006-09-27 20:39:03 :: administrator -> marciana ::
2008-05-02 14:59:03 :: marciana -> administrator ::
2013-01-11 21:19:38 :: administrator :: -> 2005
2015-05-21 14:37:46 :: administrator -> marciana :: 2005
2016-01-12 11:30:14 :: marciana -> administrator :: 2005
2018-06-04 04:12:28 :: administrator -> marciana :: 2005
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
ResumoThe ozone total column has been obtained through UV Radiation detectors as Radiometers and Spectroradiometers. It was used as an alternative method for stations which does not have expensive equipments to measure ozone like Brewer Spectrophotometers. The aim of this work is to find a mathematic model using the relation between UVB/UVA radiations ratio measured by Spectroradiometer MS 701 and effective ozone measured by Brewer Spectrophotometer MKIII #167. Both equipments are installed at Southern Space Observatory, at southern Brazil. The period selected for this analysis was the year of 2003 and only clean sky days were used. The mathematic model found was an exponential function with a correlation coefficient about 0.85. The effective ozone data obtained by Spectroradiometer were fitted with the model found and compared with the Brewer and TOMS ozone total column. The average difference between the model results and Brewer ozone total column was 0.7% and between the model and TOMS ozone data was 3.1%. It verifies the efficiency of the method used and a good approximation of the model.
ÁreaCEA
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
URL dos dadoshttp://urlib.net/ibi/6qtX3pFwXQZGivnJSY/HKJpy
URL dos dados zipadoshttp://urlib.net/zip/6qtX3pFwXQZGivnJSY/HKJpy
Idiomapt
Arquivo Alvomodelo para calculo.pdf
Grupo de Usuáriosadministrator
marciana
seeger05
Grupo de Leitoresadministrator
marciana
Visibilidadeshown
Permissão de Leituraallow from all
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Acervo Hospedeirosid.inpe.br/mtc-m18@80/2008/03.17.15.17
6. Notas
Campos Vaziosaffiliation archivingpolicy archivist booktitle callnumber conferencelocation copyholder copyright creatorhistory date descriptionlevel dissemination doi e-mailaddress edition editor electronicmailaddress isbn issn keywords label lineage mark mirrorrepository nextedition nexthigherunit notes numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress resumeid rightsholder schedulinginformation secondarydate secondarymark serieseditor session shorttitle sponsor subject tertiarymark type url versiontype volume
7. Controle da descrição
e-Mail (login)marciana
atualizar 


Fechar